What Happens During a Compressed Air Energy Audit?

Compressed air accounts for up to 40% of a plant’s total energy bill, yet most UK facilities have never had their system independently measured, modelled or benchmarked. Knowing what happens during a compressed air energy audit is the first step to closing that gap. It replaces assumptions with measured evidence of what your compressors consume and what the waste costs.

A compressed air energy audit is a site visit, a period of data logging and a written report that shows where your system wastes energy and what to change.

This guide walks through each stage as it happens on your site: the preparation, the engineer’s visit, the logging period and the report you receive at the end. It’s written by the team at Anglian Compressors, a Branch of Atlas Copco Compressors, which has been working on compressed air systems from its Peterborough base since 1977.

Contents

  • What a Compressed Air Energy Audit Measures
  • Before the Visit: Preparing Your Site
  • The Site Visit and Leak Detection
  • The Data Logging Period
  • Inside the Report: System Efficiency Findings
  • Compliance Checks an Audit Does Not Replace
  • Is an Energy Audit Worth the Cost?
  • Booking an Audit With Anglian Compressors
  • Frequently Asked Questions

What a Compressed Air Energy Audit Measures

An energy audit looks at the whole system as one machine. The compressors, dryers, filters, air receivers, pipework and every point of use all affect how much electricity it takes to deliver a cubic metre of air at the pressure your process needs.

Most sites have a reasonable idea of what their compressors are rated at. Far fewer know how those machines behave across a real production week, how much air leaks away when the lines stop, or how much pressure is lost between the compressor room and the furthest machine. The audit answers those questions with numbers you can put in front of a finance director.

Assessment, Air Audits and Full System Audits

The terms get used loosely, so it helps to separate them. A walk-through assessment is a visual inspection of the plant room and network with no logging equipment. It’s quick and gives a useful snapshot, and it often shows that a deeper look is needed.

Air audits go further by logging how the compressors run over time. A full system audit adds measurement of pressure across the network, leak surveying and modelling of the changes you could make, so each recommendation arrives with a cost and a saving attached.

Supply Side and Demand Side

The supply side is everything in the compressor room: the compressors, their controls, dryers, filtration and air receivers. Energy is lost here through machines running unloaded, poor sequencing between compressors and generation pressure set higher than the process needs.

The demand side is everything downstream. Leaks, open blowing and equipment left running on idle lines all consume air the compressors then have to make, while undersized pipework and blocked filters cause pressure drop that forces the compressors to generate at a higher pressure. A good audit gives equal weight to both, because a supply side upgrade feeding a leaking network locks the waste in.

Before the Visit: Preparing Your Site

The audit starts before anyone arrives. We ask for the basic information that lets the engineer plan where to fit loggers and what to look for:

  • A list of compressors, dryers and air receivers, with model and age where you have them
  • Shift patterns, including nights, weekends and any seasonal peaks
  • A rough site plan showing the compressor house and main air users
  • Recent service history and any known faults or pressure complaints
  • Electricity costs per unit, so the report can put a price on every finding

The Compressor Load/Duty/Cost Calculator on our website gives you a rough running cost before the audit begins. It won’t replace logged data, but it tells you whether the numbers are worth chasing.

Tell us about anything that changes demand during the logging window. A planned shutdown, a new production line or a week of reduced shifts all distort the profile if nobody flags them in advance.

The Site Visit and Leak Detection

The visit is where the engineer sees the system as it runs. It normally starts in the compressor room and then follows the air out to the production floor.

The Compressor Room Walk-Through

The engineer records each machine’s nameplate data, control settings and running hours, then watches how the compressors share the load. They check dryer type and condition, filter differential pressures, condensate drains and the size and position of the air receivers.

Ventilation matters as well. A hot compressor room raises inlet temperature, and the heat being dumped through the louvres is energy you have already paid for. Where that heat could serve a process or space heating, the visit notes it as a heat recovery opportunity.

The engineer also looks for equipment that no longer earns its place. Large networks often still carry filters or separators that serve no purpose and add pressure drop for nothing.

Walking the Distribution Network

From the compressor room, the engineer follows the main headers and drops to the points of use. They look at pipe sizing, ring mains against dead legs, wet spots where condensate collects, and the regulators and hoses at each machine.

Pressure is read at the compressor discharge and again at the furthest critical users. The difference shows how much of your generation pressure is being lost in transit, which we cover in more detail in our guide to pressure drop in compressed air systems. Every bar of unnecessary pressure the compressors make to overcome that loss is paid for in electricity.

Leak Detection on Live Lines

Leak detection usually takes the largest share of the visit. With an ultrasonic detector, the engineer can pick out leaks that are inaudible over production noise, on couplings, hose reels, push-in fittings, drains and the air side of machinery.

Each leak is recorded with its location and an estimate of its size. That list becomes a repair schedule in the report, ranked so your maintenance team fixes the biggest losses first.

The Data Logging Period

The visit captures a moment. Logging captures the pattern, and that’s where most of the savings case is built.

Loggers are fitted to record how each compressor runs over time, using current or power readings to show when a machine is loaded, unloaded or stopped. Pressure loggers sit at the discharge and at key points downstream. Where the system has a flow meter or one can be fitted, flow is logged too, along with dew point after the dryer.

Why the Logging Covers a Full Production Cycle

The logging window has to include every operating pattern your site runs. A week that covers day shifts, night shifts and a weekend shows the thing spot readings never capture: what the system consumes when nothing should be using air.

The causes to investigate are leaks, idle equipment left open and compressors kept running for a handful of small users. Seeing it plotted against the production hours tends to end any debate about whether the waste is real.

Continuous plant needs the same care. Sites that run around the clock, a familiar pattern for compressed air in the energy sector, still have load changes, maintenance windows and standby machines, and the logging window should capture them.

What Logged Data Shows That Nameplates Don’t

A fixed-speed GA 11 running at 80% load consumes close to full-load power. The logs show how many hours your machines spend in that kind of part load state, and how much of their running time is spent unloaded, drawing power while delivering no air.

The same data shows whether multiple compressors are fighting each other. Overlapping pressure bands make machines take turns cycling when one should be base-loading and another trimming, and the log makes that visible in a way no control panel snapshot will.

Inside the Report: System Efficiency Findings

The report turns the logged data into decisions. It should tell you what your compressed air costs now, where the losses are and what each change would save.

The Baseline

The baseline shows your demand profile hour by hour, the energy each compressor consumed and the cost of that energy at your unit rate. It also separates productive demand from losses, so you can see how much of the bill comes from leaks, unloaded running and excess pressure.

This is the figure every later change is measured against. Without it, any saving claimed after an upgrade is a guess.

The Recommendations

Recommendations normally fall into three groups. Some are low or no cost, such as repairing the tagged leaks, lowering the generation pressure or resetting compressor sequencing. Others need modest spend, such as replacing an undersized section of pipework, fitting zone isolation valves or adding storage.

The third group covers capital changes such as replacing a compressor, adding a GA VSD+ variable speed compressor or installing heat recovery. For these, we model the change against your logged profile using AIRchitect, the Atlas Copco energy audit tool our engineers work with, so the projected saving reflects how your site runs.

Comparing Replacement Compressors

When the report recommends a new compressor, the comparison should rest on independently checkable data. The British Compressed Air Society (BCAS), the UK trade body for the compressed air industry, runs a Performance Verification Programme for 50 Hz rotary compressors. Participating manufacturers report performance based on ISO 1217:2009 in a standard datasheet format that states Specific Power, so models from different brands can be compared by kW size and by fixed or variable speed.

BCAS selects machine samples at random for testing by an independent third-party laboratory in the UK. A verified icon on the datasheet means the compressor was selected and passed that testing.

How Recommendations Are Ranked

Each recommendation carries an estimated annual saving, an indicative cost and a payback period. That lets you work down the list in order of return rather than starting with the most visible problem.

The report also sets out the order in which changes should happen. Fix the leaks and reduce the pressure before resizing compressors, otherwise you buy a new machine sized for waste that no longer exists.

Compliance Checks an Audit Does Not Replace

An energy audit inspects the air receivers and pipework as part of the system, but it is a different job from statutory examination.

The Pressure Systems Safety Regulations 2000 (PSSR 2000) apply to pressure systems used at work in Great Britain. Regulation 8 of PSSR 2000 requires a Written Scheme of Examination for the periodic examination, by a competent person, of protective devices, pressure vessels and pipework in which a defect may give rise to danger. Regulation 9 requires the user to ensure those parts are examined by a competent person within the intervals the scheme sets.

If the audit recommends adding a receiver or changing pipework, those parts may need adding to your Written Scheme of Examination. We handle WSE work as a separate service, and we’ll flag where a recommended change is likely to affect the scheme.

Air Quality Is a Separate Measurement

Dew point logging tells you whether the dryer is doing its job, but it is not a full air purity test. Purity is classified under BS EN ISO 8573-1, which sets out contaminants and purity classes for compressed air.

The test methods sit in the other parts of the series, covering oil aerosol, humidity, particles, oil vapour, gaseous contaminants, microbiological contaminants, liquid water and solid particles by mass concentration. If your process needs a stated purity class, ask for air quality testing alongside the audit rather than assuming the energy data covers it.

Is an Energy Audit Worth the Cost?

Any audit asks something of a busy site, even when the audit itself is free. Someone has to pull together the site information, give the engineer access and keep the logging window clear of surprises. What you get back is a clear understanding of your compressed air system and the evidence to make the right changes, and that is worth far more than the effort it takes.

With compressed air taking such a large share of the energy bill, even a modest percentage improvement is worth real money. The bigger gain is that the audit stops you spending in the wrong place. A site that replaces a compressor without measuring first can end up with a new machine feeding the same leaks at the same excessive pressure.

The case is strongest on large, variable-demand sites. Our article on how compressed air supports Northampton’s logistics sites shows how energy and uptime play out on distribution operations.

Booking an Audit With Anglian Compressors

Anglian Compressors offers energy audits alongside air compressor sales, hire, servicing, repairs, leak detection, flow monitoring, heat recovery, installation and pipework. That means the team that logs your system can also carry out the changes the report recommends, and measure the result afterwards.

As a Branch of Atlas Copco Compressors, our engineers have direct access to Atlas Copco factory engineering and its proprietary diagnostic tools, including SMARTLINK, AIRchitect and AIRScan. We cover a 150-mile radius from Peterborough, across East Anglia, the East Midlands, Cambridgeshire, Bedfordshire, Northamptonshire, Lincolnshire and Hertfordshire.

You’ll find what’s included, and how we schedule the work, on our compressed air energy audit service page.

To get started, book a free energy audit and we’ll arrange the visit, the logging and the report around your production schedule.

Frequently Asked Questions

What Is a Compressed Air Audit?

A compressed air audit is a structured assessment of how a compressed air system generates, treats and distributes air. It combines a site visit, logged data and a written report that quantifies energy waste and recommends changes. Anglian Compressors offers energy audits for sites across East Anglia and the East Midlands.

What Is the Energy Audit Process?

The energy audit process has four stages. You share basic site information, an engineer visits to inspect the compressor room and survey the network for leaks, loggers record the system through a full production cycle, and the report sets out costed recommendations with payback periods.

Why Is an Energy Audit Required?

An energy audit is required because you can’t control a cost you haven’t measured. Compressed air demand changes with shifts, leaks and controls, and the electricity bill rarely shows how much of that spend produces useful work. The audit separates productive demand from waste so investment goes where it pays back.

How Often Should Compressed Air Be Tested?

Retest whenever the system changes significantly, such as a new compressor, a production line added or removed, or a move to new shift patterns. Air purity testing follows the needs of your process. Where a stated purity class matters, build regular testing into your quality plan rather than waiting for a problem.

How Do You Test Compressed Air Quality?

Compressed air quality is tested by sampling at the point of use and measuring each contaminant against the purity classes in BS EN ISO 8573-1. The test methods for particles, water, oil and microbiological contaminants are set out in the other parts of the ISO 8573 series. Our team provides breathing air quality testing.

How Is Energy Stored in Compressed Air?

Energy is stored in compressed air as pressure. Work done by the compressor raises the pressure of the air, and an air receiver holds that energy so it can be released to meet short peaks in demand. Compressed air energy storage applies the same principle at grid scale, but it is a power-generation topic and separate from a site energy audit.