Oil-Free Air Compressor Systems and ISO Class 0: Who Really Needs These Compressors?
Oil-free air compressor systems, most often built around oil-free screw compressors, keep lubricating oil out of the compression chamber. The air leaving the element carries no oil from the machine itself. Whether your site really needs one depends on what the compressed air touches and which purity class your process has to meet.
That purity class comes from ISO 8573-1:2010, the international standard that defines compressed air contaminants and purity classes. This article explains how oil-free screw compressors work, what Class 0 means in practice, which applications need it, and where an oil-injected machine with the right filtration systems still meets the specification.
It draws on our work at Anglian Compressors, a Branch of Atlas Copco Compressors, supplying and servicing compressed air systems for manufacturers across East Anglia and the East Midlands.
How Oil-Free Screw Compressors Keep Oil Out of the Air
The difference between the two designs sits inside the compression chamber. Where oil goes, and where it is kept away from, decides what reaches your air supply.
Inside an Oil-Injected Screw Element
In an oil-injected rotary screw compressor, oil is fed into the compression chamber. It seals the clearances between the rotors, carries away the heat of compression and lubricates the moving parts.
Air and oil leave the element together. A separator then removes most of the oil before the air enters the network, but some carryover remains as fine aerosol and as vapour. Downstream filtration systems are what bring that air to a cleaner purity class.
Inside an Oil-Free Screw Element
The description here applies to a dry-running oil-free screw element, the most common oil-free screw design. Its male and female rotors don’t touch each other. Timing gears hold them in step, and the gears and bearings sit outside the compression chamber, sealed from the air path.
Oil is still present in the machine, in the gearbox and bearing housings, but it’s kept out of the compressed air. Because there is no oil in the chamber to absorb heat, many dry-running designs compress in two stages with cooling between them. Water-injected screw compressors take another route, using water rather than oil to seal and cool the element.
Key mechanical differences between an oil-injected and a dry-running oil-free screw compressor:
- Lubrication: oil in the compression chamber versus no oil in the compression process
- Cooling: oil acts as coolant and sealant versus air or water cooling with intercooling between stages
- Oil separation: a separator element and oil carryover to manage versus no compression oil to separate
- Oil changes: compressor oil and separator changes on an oil-injected unit versus gearbox oil on an oil-free unit, which never contacts the air
What ISO 8573-1 Class 0 Means for Your Specification
ISO 8573-1 groups the contaminants in compressed air into purity classes. The rest of the ISO 8573 series sets the test methods used to measure each contaminant against those classes.
Class 0 is the ISO 8573-1 purity class associated with oil-free compressed air.
Treat it as a specification rather than a label. The oil limit your process can tolerate, and the class that limit corresponds to, should be agreed with your supplier, written into the specification for each point of use and then verified by measurement. Whether you need Class 0 follows from that limit, not from the compressor brochure.
How Oil Content Is Measured
Oil in compressed air exists as aerosol and as vapour, and the ISO 8573 series measures them separately. ISO 8573-2:2018 covers the test method for oil aerosol content, and ISO 8573-5:2025 covers oil vapour content.
A meaningful oil claim considers both. Other parts of the series cover particles (ISO 8573-4:2019), humidity (ISO 8573-3:1999) and viable microbiological contaminants (ISO 8573-7:2003), so a complete air quality survey can test the whole specification.
For a fuller explanation of the classes and how to read a specification, see our practical guide to ISO 8573-1.
Why Intake Air Still Matters
An oil-free compressor removes compressor oil from the equation. It can’t remove what the air already contains when it’s drawn in.
Ambient air on an industrial site can carry hydrocarbons, dust and moisture. Even an oil-free compressor normally needs drying and filtration at the point of use to hold the full specification, which is why we always look at the complete air supply, not the compressor alone.
Which Applications Really Need Class 0 Air?
The deciding question is simple. Does the compressed air contact your product, your packaging or a person, and what happens if oil gets through?
Food, Beverage and Pharmaceutical Production
Where compressed air touches food, drink, tablets or primary packaging, oil contamination becomes a product safety and recall risk. Oil-free air compressor systems remove the compressor as a source of that oil, which simplifies the risk assessment. Drying and filtration downstream then deal with moisture, particles and anything drawn in with the intake air.
Electronics and Precision Manufacturing
In electronics manufacturing, compressed air often contacts circuit boards, components or optics directly. Any oil it carries becomes a contamination risk to the product, so air purity bears directly on yield and rework. That makes oil-free supply worth assessing for the processes where air meets the product.
Sensitive Processes in General Manufacturing
Paint finishing, instrument air and process air that contacts the product can all justify oil-free supply. Elsewhere on the same site, tool air and general utility air may not.
On a site like that, a mixed system is worth assessing, with oil-free air for the sensitive lines and treated oil-injected air for everything else. Our page on compressed air for the manufacturing industry covers how we approach mixed-demand sites.
When Oil-Injected Compressors With Filtration Are Enough
Not every site needs oil-free screw compressors. Pneumatic tools, cylinders, blowing and general workshop air rarely need oil-free air.
For those duties, an oil-injected compressor with a dryer and correctly sized coalescing and activated carbon filters can be specified to meet the oil class the application calls for, provided the result is verified at the point of use. The trade-off is that the result depends on maintenance. Filter elements must be changed on schedule, and a saturated or bypassed filter lets oil through.
If the consequence of that failure is a scrapped batch or a recall, the risk calculation changes. If it is a slightly oily air tool, it usually does not. We’ve compared how oil-injected and oil-free designs differ in more depth in a separate guide.
Running Costs, Efficiency and Compliance
The purchase price is one part of the comparison. Running cost depends on energy use, filtration, maintenance and the cost of contamination risk.
Comparing Energy Performance Fairly
The British Compressed Air Society (BCAS) runs an independent Performance Verification Programme for 50 Hz rotary compressors. Participating manufacturers report performance based on ISO 1217:2009 in standardised datasheets that show Specific Power, so models can be compared by kW size and by fixed or variable speed.
BCAS also selects machine samples at random for testing by an independent UK laboratory against the manufacturer’s published ratings. Comparing BCAS verified datasheets is a fairer route than comparing brochure figures.
Pressure Systems Duties Still Apply
Choosing oil-free doesn’t remove statutory duties. The Pressure Systems Safety Regulations 2000 (PSSR 2000) apply to pressure systems used at work in Great Britain, whatever the compressor technology.
Regulation 8 requires a Written Scheme of Examination for the periodic examination, by a competent person, of protective devices, pressure vessels and pipework in which a defect may give rise to danger. Regulation 9 requires the user to make sure those parts are examined within the intervals the scheme sets.
How to Specify an Oil-Free Air Compressor System
A sound specification starts at each point of use and works back to the compressor room:
- Map every point of use. Note what the air contacts and the consequence of contamination at each one.
- Assign a purity class. Set the ISO 8573-1 class for each contaminant at each point of use, not one class for the whole site.
- Decide where oil-free air applies. If a single line needs it, compare a dedicated oil-free supply against treating the whole network.
- Size flow and pressure. Base the compressor and dryer selection on measured demand.
- Plan verification. Agree how and how often air quality will be tested against the specification.
Oil-Free Screw Compressors From Anglian Compressors
We supply, install and service oil-free compressed air systems alongside air dryers, filtration and pipework, so the purity achieved at the compressor holds at the point of use. Our team also carries out breathing air quality testing, energy audits and Written Scheme of Examination work.
Our range includes the ZT 30-50 Variable Speed Drive (VSD) oil-free compressors. We start from your purity specification and demand, then recommend oil-free or oil-injected equipment to match.
Frequently Asked Questions About Oil-Free Air Compressors
What Are the Downsides of Oil-Free Air Compressors?
The main downside is mechanical complexity. Dry-running designs use timing gears and often two-stage compression, and servicing needs engineers trained on oil-free elements. Compare cost on quotations for equivalent output, including treatment, energy and maintenance. Anglian Compressors offers servicing packages that cover oil-free machines.
Are Oil-Free Air Compressors Worth It?
They’re worth it where oil in the air would damage product, packaging or people, and where filtration failure would be costly. For general tool and utility air, the answer depends on comparable quotations for the compressor, treatment, energy and maintenance. Our team can assess which applies to your site.
Which Is Better, an Oil-Free or Oiled Air Compressor?
Neither is better in every case. Oil-free suits processes where air contacts the product, while oiled compressors with filtration suit general manufacturing duties. Anglian Compressors offers both, and the right choice follows from your purity class and the cost of contamination.
How Long Do Oilless Air Compressors Last?
Service life depends on the model, duty cycle, ambient conditions and maintenance, so a realistic estimate needs those details. An industrial oil-free screw compressor serviced to its schedule, with the screw element overhauled when its condition requires, can run for many years.
If you are reviewing air quality on a critical line, start with the specification at the point of use. Our team can review your purity specification and measure your air demand, then show whether oil-free air compressor systems are justified. Talk to our team or ask about a free energy audit.