How Much Compressed Air Does a Nitrogen Generator Need?

Adding a nitrogen generator to an existing compressed air system can leave production competing for air. The generator may meet its nitrogen specification in isolation, then lose inlet pressure when the rest of the factory reaches peak demand.

Required compressed air flow equals nitrogen flow multiplied by the generator’s air factor, using compatible flow reference conditions.

That calculation establishes the generator’s demand. Whether your existing compressor can supply it also depends on simultaneous site consumption, pressure losses, air treatment and storage.

At Anglian Compressors, a Branch of Atlas Copco Compressors, we assess those requirements together. A compressor’s motor rating alone cannot tell you whether a new nitrogen installation will work.

Establish the Nitrogen Specification Before Calculating Air Demand

Start with the process requirement at the point of use. Record the nitrogen purity, required delivery pressure, normal consumption and highest sustained flow, plus the duration and frequency of short peaks such as vessel purging or packaging-line start-up. A brief peak that storage can support is a different sizing problem from a flow the generator must maintain throughout a shift.

Our explanation of how a nitrogen generator works covers the separation process. Pressure swing adsorption (PSA) is the usual starting point for high-purity nitrogen, and membrane generation is an option where the application accepts lower purity. Our Atlas Copco nitrogen generator range includes both technologies.

For compressor sizing, the relevant question is how much feed air the selected model consumes while delivering your specified nitrogen.

Use the Air Factor for the Selected Operating Point

The air factor expresses the relationship between compressed air consumption and nitrogen production:

Q_air = Q_N₂ × AF

Here, Q_air is the required feed-air flow, Q_N₂ is the nitrogen delivery flow and AF is the air factor. Purity, inlet pressure and inlet temperature all change that relationship, so obtain the air factor for the exact model and operating point rather than applying a general PSA or membrane multiplier.

A higher purity requirement can increase compressed air demand and reduce the nitrogen flow available from a given generator. Our article on how gas purity affects cost explains the commercial effect. Confirm the process requirement before adding extra purity as a precaution.

Put Compressor and Generator Flows on a Common Basis

A compressor specification normally states free air delivery (FAD) at stated reference conditions. Generator documentation may use normal cubic metres per hour, standard cubic feet per minute or another defined basis, and identical-looking units do not guarantee identical reference temperature, pressure and humidity.

Use compressor FAD at the proposed discharge pressure. Motor power, displacement and receiver capacity cannot replace a delivered-flow figure. Our guide to reading an air compressor specification sheet explains the relevant fields. Convert every flow to a compatible basis before subtracting site consumption from compressor capacity.

Worked Example: Can the Existing Compressor Supply It?

The following is a hypothetical specification example, not performance data for a particular generator or compressor.

Assume the proposed generator must deliver 30 m³/h of nitrogen at 99.9% purity. Its hypothetical supplier specification gives an air factor of 3.0 at 7 bar(g) inlet pressure and 20°C inlet temperature, with all flows already expressed on the same dry-gas reference basis of 20°C and 1 bar absolute.

The generator needs 30 × 3.0 = 90 m³/h of compressed air, or 1.5 m³/min. Assume the existing compressor can deliver 5.0 m³/min at the discharge pressure needed to hold the generator’s inlet requirement.

Demand or CapacityHypothetical Flow
Compressor FAD at the required discharge pressure5.0 m³/min
Existing simultaneous site demand, including measured leakage2.8 m³/min
Nitrogen generator feed-air demand1.5 m³/min
Additional treatment and auxiliary air consumption0.2 m³/min
Total combined demand4.5 m³/min
Remaining capacity0.5 m³/min

The arithmetic shows enough flow for this operating point. It does not yet show the installation is suitable. The remaining capacity must cover the agreed operating reserve and any demand the measurements missed. Check whether the generator’s stated consumption already includes its own regeneration air, or you may count the same demand twice.

A shift-average flow can conceal simultaneous peaks, so measure across start-up, changeovers and the busiest operating periods. Our gas generation work includes the compressed air system that feeds it.

Maintain Pressure at the Generator Inlet

The generator’s inlet pressure requirement applies at its connection while air is flowing. A satisfactory compressor-room gauge reading does not establish that pressure at the generator.

Dryers, filters, valves and pipework all lose pressure. Assess them at the required flow, including the drop expected as filters approach replacement. In the example, the generator needs 7 bar(g) at its inlet, so the compressor discharge pressure must cover the losses in between, and its FAD must be checked at that higher pressure. Raising the whole factory’s pressure should not be the default response.

Specify Air Treatment and Storage at the Generator Connection

Specify the required air quality at the generator inlet rather than relying on the compressor’s description. The NGP/NGP+ technical tables in our Atlas Copco industrial gases brochure state an inlet quality of ISO 8573-1:2010 Class 1.4.1, covering particles, water and oil in that order.

That is a requirement for that equipment, not a universal specification. Check the dryer against the total flow that will pass through it once the generator is connected, and include any treatment air consumption in the capacity calculation.

Air receivers can support transient feed-air demand, while a nitrogen buffer can support short process peaks. Storage cannot correct a sustained shortfall: if average nitrogen consumption exceeds generation capacity, the buffer will eventually run down.

New receivers, PSA vessels and nitrogen buffers also change the pressure system, so the site’s Written Scheme of Examination should be reviewed to cover them before the generator goes into service.

What We Need to Check Your Existing Compressor

Send us the process demand profile, generator performance requirements, compressor model and pressure settings, existing treatment details and any monitoring data. Include planned production changes and how long the process can tolerate an interruption.

Book a free energy audit and we will data-log your system for 7–10 days to show whether the existing compressor can feed the generator at peak demand. If you already know you need a dedicated supply, use the same form to request a quote.